technical specification
Frequency Band
- Rx 1525.0 - 1559.0MHz
- Tx 1626.5 - 1660.5MHz
- Ch width 10.5-189kHz.Rx, 21-189kHz Tx
Power supply and Consumption
- DC input range (isolated): 10 to 32V DC
- Power (max): 150W @ 10-32V
Environmental Conditions
- Ambient Temperature: -25°C to +55°C
- Storage: -40°C to +85°C
- Survival (power on, non functional): -40°C to +80°C
- Automatic thermal surveillance shuts down system gradually in ease of own temperature
- BDU operating humidity: 95% non condensing at +40°C
- ADU enclosure: IPX6
- ADU operating humidity: Exposed aaccording to EN60 945
- BDU enclosure: IP31
- Icing (survival): Max 25mm
Vibration
- Vibration, operational: Random spectrum 1.05g ms x 3axes, 5 to 20Hz; 0.02g2/Hz
- Vibration, non operational: Random spectrum 1.7g rms 2h x 3axes (6h total), 5 to 20Hz 0.02g2/Hz, 20 to 150Hz;-3dB/octave
Antenna Connector
- ADU: TNC/female
- BDU: TNC/female
Mechanical Shock